F5
- E0 Door switches do not agree (condition
exists when door switch is closed indicating an open door, and latch switch is
closed indicating a locked door) 1. If door latched:
switch to control. If no damage to wires and all connectors okay, proceed to
step C.
memory. F2 will appear. Press CANCEL and observe for 1 minute to ensure
operation is correct.
2. If door not latched:
switch to control. If no damage to wires and all connectors okay, proceed to
step C.
3. Measure door switch (door open = switch open small low voltage terminals).
Replace switch if defective.
4. Measure latch switch (unlatch = switch open,
CAUTION - oven light contacts are closed). Replace switch if defective.
5. If
corrections are made in any step, reconnect power to control. Press and hold any
key for 1 minute to clear R failure code from memory. F2 will appear. Press
CANCEL and observe for 1 minute to ensure operation is correct.
6. If failure
remains, disconnect power and replace control.
Note:
Applies to all F5-E... codes.
1,127 views
Usually answered in minutes!
Worked on a stove with the code f5e0 we fixed it by open the stove door and holding down the black door pin in the upper right had corner then pushing back on the door lock then close the door fixed. Hope this helps with your problem this is how I fixed ours.
×