DL = Long Drain
Ld flashes when the water level does not change after the drain pump is on.
Is the drain hose or the drain pump clogged?
Is the drain hose height greater than 96? ?
Perform the following checks if washer fails to drain or recirculate.
1. See Activation of Manual Diagnostic Test Mode, and perform the Manual: Pumps test.
2. Remove the console to access the machine/ motor control assembly. See Accessing & Removing the Electronic Assemblies.
3. Visually check that the P4 connector is inserted all the way into the machine/motor control. If visual check passes, go to step 4. If visual check fails, reconnect P4 and repeat step 1.
4. Remove connector P4 from the machine/ motor control and check resistance values of pump motor windings. Resistance values should match those shown in wiring diagram, page 7-1. If resistance values are good, go to step 7. If winding measurements are much higher (tens of ohms to infinity) than shown in wiring diagram, a problem exists in the motor winding or in the connection between the machine/motor control and the motor. Go to step 5.
5. Tilt machine forward to access the bottom of the machine and the pumps. See Figure 1, page 6-13.
6. Check the resistance at the pump motor. Remove the connector at the motor and take measurements across pump terminals. Measurements should be as shown in the wiring diagram. If winding measurements are much higher (tens of ohms to infinity) than shown in wiring diagram, replace the pump motor. If the resistance at the pump motor is correct, there is an open circuit in the wiring between the motor and the machine/ motor control. Repair or replace the lower wiring harness. If the pump motor windings and machine/ motor control check OK, repair or replace the pump. Be sure to check the pump and tub sump for foreign objects before replacing pump.
7. See Activation of Manual Diagnostic Test Mode, and perform the Manual: Pumps test.
8. If the Manual: Pumps test failed, then the machine/motor control has failed: Unplug the washer or disconnect power. Replace the machine/motor control assembly. Perform the Manual: Pump test.
DnC Sourcing is to make an Expert of developing products. ---> www.artdnc.com (82) 70-7893-2100)http://www.sourcingbuysell.com
We have 15 years developing experiences and will implement the advanced products to our customer.
Electronics, home appliances, sporting goods, medical products, smart phone, General Phones, machine equipment, cattle. Midsize engine
* Mechanical design, tooling, product design, machine design, reverse engineering (image), product design, MOLD Analysis
* Processor: AVR series, DSP, FPGA, ARM7, ARM9, etc.
* Circuit design, PCB ARTWORK Use Program: ORCAD, PADS
70% Motor Sales ---> www.buysellmotor.net, sourcing everything ->http://www.sourcingbuysell.com
×
312 views
Usually answered in minutes!
×