Questions & Answers for: True e1 controller Home

Replacing a temp control valve on a true GDM 26 commercial refridgerator Hi, I have a True Model GDM 26, and I need to replace the temperature control valve. The plate with the control knob is on the ...

Ad

Question about GDM-41 Refrigerator

1 Answer

no power to compressor Probably the cold control (or thermostat ) is bad .Unplugged the unit and bypass the cold control by putting together the two wires and wrapping them with electrical tape . If ...

Ad

Question about GDM-12 Refrigerator Commercial

1 Answer

True GDM 12 won't go over 57 degrees. Just got it,older model no T-Stat. Cleaned up last night did see some brown syrup looking stuff.I did wait about 8 - 10 hours before pluging in. The unit has been

Question about TBB-2 Beverage Cooler

1 Answer

true cooler frezzing kegs of beer I have just started having a problem with my true cooler frezzing my kegs of beer whta temp should I dial it on to solve this prblem If I am not mistaken, the True ...

Question about GDM-23 Refrigerator Commercial

1 Answer

I have a true upright commercial display refrigerator.I think the tempature control is faulty.It freezez everything,I use it for beer and wine.I have cleaned the condensor and still no luck.No matter ...

Question about GDM-26 Refrigerator

1 Answer

I have a True GDM-26, that I determined had a bad temp control. I ordered a new control from a company the referenced the part number by unit model number. I did not take the original control to match

Question about 72 cu. ft. / 2039 liter Commercial Freezer T-72F

1 Answer

P-1 code is flashing on temperature display P1 is almost always a fault on the sensing (control) probe. Check it's end is not wet or covered in thick ice, and check the connections at the ...

How do I calibrate the temp. control on a GDM-23 that runs too cold 32-25? If you cant get the control warm enough there are a couple of possibilities. First:You recently had gas put in the system and

Question about TS-49F Stainless Steel Freezer 2 Doors 49 cu ft

1 Answer

What is the standard defrost timer control setting Usually every 6 hours will keep the evaporator coil clear of frost. I set the time at 45 minutes per defrost. This unit has a defrost termination ...

...on units with Dixell electronic controls. "E1" . .. E1 is error code for air temp probe 1 has failed. Need to have it checked to be sure it a bad probe (sensor) or a bad connection/bad