Anonymous posted an answer for this Heating & Cooling:
"remote is ok but not operating"
Anonymous posted an answer for this Heating & Cooling:
"check the electronic control board."
Anonymous posted an answer for this Heating & Cooling:
"Onida split Ac displays F5/F6 error and trips immediately after starting. Since display is..."
Anonymous posted an answer for this Heating & Cooling:
"F6 error is related with the indoor blower motor check the return signal wire of motor..."
Anonymous posted an answer for this Heating & Cooling:
"Unit stopped working so I took off the cover and found the fan not working so I pushed by..."
Anonymous posted an answer for this Heating & Cooling:
"check the indoor fan motor by this method switch on the unit check whether the motor is..."
Anonymous posted an answer for this Hampton Bay HBLG5004 Air Conditioner:
"it is normal when the compressor start because the starting current of the compressors 5-8..."
Anonymous posted an answer for this Hampton Bay HBLG5004 Air Conditioner:
"It gets really load when the compressor kicks on?"
Anonymous posted an answer for this LG Art Cool LA1000PR Air Conditioner:
"first of all check the outdoor unit if it is in your reach than simply touch both..."
Anonymous posted an answer for this LG Art Cool LA1000PR Air Conditioner:
"Installed an artcool in my appartment and it constanly leaves a little puddle of water on..."
Anonymous posted an answer for this Refrigerators:
"we have a beko cg9956ffw fridgw freezer and we want to know how to turn the temp down on..."
Anonymous posted an answer for this Refrigerators:
"yes this is the coldest temp.move it toward anticlockwise to decrease the temp."
Anonymous posted an answer for this Heating & Cooling:
"My indoor fan comes on but the compressor does not. I checked voltage, fuses and wiring..."
Anonymous posted an answer for this Heating & Cooling:
"as u written here that the power is their in coil voltage than check for the neutral..."
Anonymous posted an answer for this Panasonic CW-1406BU Air Conditioner:
"check for the run capacitor and the current of the machine."
Anonymous posted an answer for this Panasonic CW-1406BU Air Conditioner:
"compressor shuts off to soon . panosonic model cw1406bu"
Anonymous posted an answer for this Samsung AS18A6RB Air Conditioner:
"My Sansung Ac just shuts off by itself every 25 minutes or so and does not come on itself...."
Anonymous posted an answer for this Samsung AS18A6RB Air Conditioner:
"check for the return fan motor wire signal for pcb"
Anonymous posted an answer for this Samsung AS18A6RB Air Conditioner:
"samsung spilit ac 1.5ton airconditioner indoor pcb fault so how direct connection to..."
Anonymous posted an answer for this Samsung AS18A6RB Air Conditioner:
"it is not advisable to directly connect the fanmotor ,but if still u want to connect it..."
Anonymous posted an answer for this Goldstar Heating & Cooling:
"check for the small hole below the fan motor for moisture of back evaporating coil"
Anonymous posted an answer for this Goldstar Heating & Cooling:
"gold star mural air condtioner model numberGS120ce. ac leaks down my wall and the pan is..."
Anonymous posted an answer for this Sharp CV-P10LC Portable Air Conditioner:
"check for the clogged evaporating coil"
Anonymous posted an answer for this Sharp CV-P10LC Portable Air Conditioner:
"I have checked the unit and can't find out why it is not blowing cold air. It slowly..."
Anonymous posted an answer for this Sanyo Split System Air Conditioner:
"it is happening due to blower motor not giving the signal to pcb pls check their is a..."
Anonymous posted an answer for this Sanyo Split System Air Conditioner:
"I HAVE SPLIT AIR CONDITIONER SANYO SAP-K185 GHS4/CB SER.NO9003258 AND WORKED PERFECTLY..."
Heating & Cooling 12 answers