Questions & Answers for: external heat roll

Question about DocuColor 12 Color Copier

2 Answers

...for this fault code is: External Heat Roll Contact Failure. Generally the external heat roll retract motor is defective. The xerox part number of this motor: 127K21350 cambia el motor del ...

Ad

Question about DocuColor 12 Printer

1 Answer

error 10-356 and 10-355 error 10-356 and 10.355 10.356 external heat roll retract failure. Try to release the external heat roll maybe something stop the rotation

Ad

Question about DocuColor 12 Printer

1 Answer

xerox dc 12 eror 10-356 eror 10-356 U have problem with external heat roll sensor. Maybe is dirthy or broken. Try clean or replace

heat you are in points in that direction. Did you recently install any kind of external fan, wood fireplace or another gas appliance. Any of these could cause what you are experiencing. .Make sure the

Question about Raypak 130,000 BTU Propane Gas Pool H...

1 Answer

external part that looks like a resistor. This part detects flame/heat coming out from the burner tray. When replacing it, be sure to check for blockage at the burner tray, heat exchanger and the flue

Question about Rp2100 Pool & Spa Heater Lonox 407k Btu Natural Gas Polymer Header Digital Rp407aenc

1 Answer

external part that looks like a resistor. This part detects flame/heat coming out from the burner tray. When replacing it, be sure to check for blockage at the burner tray, heat exchanger and the flue

Question about Free Hydraulic Lift Gate Delivery - No L...

1 Answer

external part that looks like a resistor. This part detects flame/heat coming out from the burner tray. When replacing it, be sure to check for blockage at the burner tray, heat exchanger and the flue

Question about DocuColor 12 Printer

1 Answer

what about the code 10-386 & how to solve it ? Reposition the thermistors against the External Heat Roll.

Question about DocuColor 12 Printer

1 Answer

external heat roll sensor did not go low within 5 seconds and 356 ext. heat roller did not go high after 5 seconds the sensor sits by the web motor check the flag is not missing the sensor will go bad

...External Heat Roll Overheat Thermistor, and the Inlet Roll Control Thermistor all Indicate an Over Temperate Condition. Aug 13, 2015 Fault Code 10-355: A Hard Overheat Fault has been Detected ... ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Office Equipment & Supplies Experts

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

73781 Answers

ADMIN Eric
ADMIN Eric

Level 3 Expert

42221 Answers

Brad Brown

Level 3 Expert

19190 Answers

Are you an Office Equipment & Supplies Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...