EXPOBAR Recent Questions, Troubleshooting Help & Support

Do you work here? Claim your company

  • 12 Products
  • 56 Answers
  • 11K Views
0helpful
1answer

I have changed coffee grind and descaled machine,

You might have a bad seal.
11/10/2012 5:14:39 AM • EXPOBAR Office... • Answered on Nov 10, 2012
0helpful
1answer

We have an Expobar Office

Hi
If its pumping water its not the thermal fuse. Its probably the heating element. If it starts to build pressure but stops, its your vacuum breaker. It could also be your CPU is bad. Need a little more information to get a better handle on it.
5/19/2011 10:08:14 PM • EXPOBAR Office... • Answered on May 19, 2011
0answers
0answers
0helpful
1answer

My expobar brewtus switcherd off

Most likely the heating element has burned out and shorted. This is an advanced repair that we do.
www.dolcevitaespresso.com
2/15/2011 10:28:41 PM • EXPOBAR Brewtus... • Answered on Feb 15, 2011
0helpful
1answer

I just bought this Office

These two problems can be related.
If the water temp is low, You are NOT going to get a good extraction (almost no crema).
wait like 20 min. before using the machine, And if there is a pressure gauge (on the machine) it has to be in the 1 to 1.2 range.

Always warm up the portafilter/handle before use.
If the water is hot and there no crema, Adjust the grinder.
The group temperature is about 212f for commercial espresso machines.
1/14/2011 11:16:31 PM • EXPOBAR Office... • Answered on Jan 14, 2011
0helpful
1answer

I have a brewtus lll-V

That sounds more like a safety valve issue than the vent valve, that is poping because of too much pressure, try lowering the pressure stat on the machine, or replacing it.
1/5/2011 1:28:09 AM • EXPOBAR Brewtus... • Answered on Jan 05, 2011
0helpful
1answer

Safety valve cn10 keeps activating about 10

Try this open the steam wand and leave on when turning the machine on, when valve stats hissing with steam close. If that works then the vent valve needs to be replaced, If it blows out hot steam from valve then the pressure stat is not operating properly.
7/2/2010 10:09:38 PM • EXPOBAR Office... • Answered on Jul 02, 2010
0helpful
1answer

How can I increase the pressure for the steam wand?

If boiler pressure is set to about 1.2 bar on machine and you are getting no steam then check the nozzle on the steam wand, that might be blocked, before adjusting the pressure stat in the machine.
5/31/2010 6:07:24 PM • EXPOBAR Brewtus... • Answered on May 31, 2010
Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top EXPOBAR Experts

Ernest R
Ernest R

Level 3 Expert

1618 Answers

Anonymous

Level 1 Expert

5 Answers

Anonymous

Level 2 Expert

153 Answers

Are you an EXPOBAR Expert? Answer questions, earn points and help others

Answer questions